Sorensen Ethernet Option

Configuration

M130/M131 Programming Manual

2-19


Primary: Obtain an IP Address Automatically (DHCP) and AutoIP Enabled

Secondary: no matter the setting, will never be attempted

At power-up the power supply will attempt to acquire an IP address from a DHCP
server. If it cannot find a DHCP server to assign an address, it will assign itself a
link-local address. If no other device is using that link-local address, it will use it
for 5 minutes minimum. At that time, if it is already in communication with some
other device, it will hold onto the link-local address until the communication is
finished and then retry DHCP. If DHCP is not available, the power supply will
revert to the last successful link-local address for another 5 minutes minimum.


Primary: Obtain an IP Address Automatically (DHCP)
Secondary: Use a Static IP Address

At power-up the power supply will attempt to acquire an IP address from a DHCP
server. If it cannot find a DHCP server to assign an address, the power supply will
move to Secondary and assign itself the static IP address. If no other device is
using the IP address, the power supply continues with that static IP address. If
some other device is using the static IP address, the power supply will move back
to Primary and start the entire operation again

SETTINGS

The Settings page is available to users who have FULL, Read/Write or Read
Only access to at least one power supply (Read Only users can make no
changes to the settings). If you have a system with a single master and many
slaves, you could have access to one or more individual power supplies in the
system (see SECURITY pages).