{Add username and password in command line.} For all IE version, include 7.0 and above


User
s
can
contr
ol
the
9222
’s
actio

n directly though the HTTP orders.

The syntax of the HTTP commands are listed below:
Command format:

http://admin:password@ipaddress/Set.cmd?CMD=CmdType


*Http Function of 9211:

GetIO

Command format: http://admin:pasword@ ipaddress/Set.cmd?CMD=getio

http://admin:[email protected]/Set.cmd?CMD=getio

Output Message will return:
P51=0, P52=1, P53=0, P54=1, P55=0, P56=1, P57=0, P58=1

What this means is:
P5

: Represents that this input message is from 9201 Input Module

(The P51 corresponds to the output port number. P51 = Input Module Port 1 P52 = Input Module Port 2
and so on).

The 0/1 after each Output

: Represents whether there has been a status change or not.

0 = Keep Current Status
1 = Change Current Status

So for our current output message:
P51=0,P52=1P53=0,P54=1P55=0,P56=0,P57=0,P58=1HTTP/1.0 200 OK Connection: close

P52 = 1: Output 2: Status - On
P57 = 0: Output 7: Status - Off
P58 = 1: Output 8: Status - On

http://admin:[email protected]/Set.cmd?CMD=GetIo


Please refer to the chart provided for more information:
Input Number (Default)

Default Status

Status Change

Input 1: Wet

Status = Off

Status = On

Input 2: Wet

Status = Off

Status = On

Input 3: Wet

Status = Off

Status = On

Input 4: Wet

Status = Off

Status = On

Input 5: Dry

Status = On

Status = Off

Input 6: Dry

Status = On

Status = Off

Input 7: Dry

Status = On

Status = Off

Note:

IP Power 9202 Output Pro has predefined Relay Statuses.
Outputs 1 - 4:

Normal Closed Relay

(NC)

Outputs 5 - 8:

Normal Open Relay

(NO)

(The relay status of the outputs cannot be changed: Meaning that Output 1-4 will

always be

Normally closed

and Outputs 5-8 will always be

Normally Open

)