Comtech EF Data SFC4200 User Manual

Page 36

Advertising
background image

User Interfaces

SFC4200/SFC1275G Synthesized Frequency Downconverter

4-12

TM054 - Rev. 4.0

These include the following:

Prime Not Learned:

The Backup has not learned about the Prime(s).

Prime Polling Error:

Either the Prime did not respond to the Backup’s
periodic polling, or something in the Prime’s
configuration has changed since the last time the
backup was told to ‘Learn.’

Note: Changing the Prime after the Backup has ‘Learned It’ will cause a Switch Fault until
the Backup is told to ‘Relearn’ the Prime(s).

Prime Relay Fault:

The Backup has detected that the Switching Relay did
not switch when told to do so.

Note: Any Switch Fault will cause the Signal Fault LED on the Backup to illuminate. It
will also cause the Error LED on the 1:8 Switch to illuminate.

4.2.4 Converter Faults Menu

To access the Converter Faults Menu, depress <ENTER>. If there are no stored faults, the fault
menu will indicate ‘Stored Faults, None.’ If there are stored faults, the menu will indicate that
stored faults have been recorded.

To interrogate the nature of the stored faults, depress <ENTER> again. The stored fault screen
format is as shown in Figure 4-8.

Figure 4-8. Stored Faults Menu

The Fault descriptions are indicated as follows:

LO:

Indicates a fault in the synthesizer and the number of fault detections
(up to 255).

SIG:

N/A

To clear the faults, depress <ENTER>.