Comtech EF Data SFC4200 User Manual

Page 48

Advertising
background image

User Interfaces

SFC4200/SFC1275G Synthesized Frequency Downconverter

4-24

TM054 - Rev. 4.0

4.5.14 Restart (All)

This command allows the user to reset/restart the converter.

@01/RESTART<cr>

4.5.15 Data (All)

This command will cause the converter to display the applicable data formats for the various
commands.

@01/DATA

4.5.16 Learn (B1:1, B1:8)

In a 1:1 Switch configuration, this command will cause the backup converter to ‘Learn’ about the
Prime converter.

In a 1:8 configuration, the Backup converter will ‘Learn’ about the Prime converters that have a
priority > 0. As the Backup converter polls the Prime(s), the learning status will be output via the
serial port.

@01/LEARN

4.5.17 Show Priority (B1:8)

This command causes the backup converter to display the priority settings for all 8 of the prime
converters.

@01/SHOW PRI (1:8 configuration only)

4.5.18 Set Priority (B1:8)

This command is used to set the priorities of converters 1 to 8 respectively where:

0 = No priority (the converter will be ignored)
1 = Highest priority
8 = Lowest Priority

@01/SETPRIabcdefgh (1:8 configuration only)

For example: @01/SETPRI47300000 will cause the following to occur:

Converter 1 will have priority 4;
Converter 2 will have priority 7;
Converter 3 will have priority 3;
Converters 4 through 8 will be ignored.