9 operation serial i/o (j8) – Comtech EF Data SFC4200 User Manual

Page 54

Advertising
background image

Electrical Interfaces

SFC4200/SFC1275G Synthesized Frequency Downconverter

5-4

TM054 - Rev. 4.0

5.9 Operation Serial I/O (J8)

The Operation Serial I/O Port (J8) is a D Sub 9-Pin Female Connector. This port provides a
serial interface that can be configured as either an RS-232, RS-422 or RS-485 interface and
allows the user to remotely control all of the features outlined in the Serial Protocol. The serial
port comes configured as an RS-232 Serial Port for DCE unless indicated otherwise. The
pinouts of the D-Sub 9-Pin Socket Connector configured for RS-232 or RS-422/-485 is listed in
Table 5-4.

Table 5-4. J8 – Operation Serial I/O Port – D Sub 9-Pin Connector

Pin No.

RS-232

RS-422/-485

AS/3048

(J10)

1

N/C

RXData\

1

2

TXData

TxData

3

3

RXData

RxData

5

4

DTR to Pin 6

DTR to Pin 6

7

5

GND

GND

9

6

DSR to Pin 4

DSR to Pin 4

2

7

RTS to Pin 8

RTS to Pin 8

4

8

CTS to Pin 7

CTS to Pin 7

6

9

N/C

TxData\

8

Note: In order to obtain these signals at the output connector, the jumper configuration
on the AS/3048 Controller PWB must have been performed as illustrated in Figures 5-4
through 5-7. A summary of the jumper selections is as follows:

Configuration

JP4-1 JP4-2

JP4-3 JP4-4 JP4-5

JP4-6

JP3

JP5

JP6

JP7

JP8

RS-232

OUT

OUT

OUT

OUT

IN

IN

OUT

OUT

IN

OUT

OUT

RS-422

IN

IN

IN

IN

OUT

OUT

OUT

*

OUT

OUT

OUT

IN

RS-485

IN

IN

IN

IN

OUT

OUT

OUT

*

OUT

OUT

OUT

IN

RS-485 1/2 DPLX

IN

OUT

OUT

IN

OUT

OUT

OUT

*

IN

OUT

IN

IN

* Receiver terminations for twisted pair RS-422/-485 can be optionally terminated at 120
Ohms by installing JP3. Factory-supplied cables for multiple converter "daisy chain"
operation are terminated at the cable ends.

The serial protocol is designed to provide DTE-to-DCE Point-to-Point Communications. The
converter is wired as the DCE to provide an interface to a dumb terminal (DTE) without a null
modem connection. Because the serial protocol uses unique addressable commands, the
converters are capable of providing multipoint communications between a number of converters
and a customer-supplied serial interface. The typical multipoint communications configurations
include full- and half-duplex RS-485. In addition, a multipoint RS-232 interface is also possible.