Comtech EF Data SFC4200 User Manual

Page 46

Advertising
background image

User Interfaces

SFC4200/SFC1275G Synthesized Frequency Downconverter

4-22

TM054 - Rev. 4.0

A Primary Converter in a 1:8 Switch configuration will issue the following string of information:

Switch Configuration:

{Auto, Manually Selected, Manually De-selected}

Primary Converter Number:

{01, 02, 03, 04, 05, 06, 07, 08}

Status:

{Available, Faulted}

Channel:

{Current Channel}

Frequency:

{Current Frequency}

Gain:

{Current Gain}

RSS:

{Text, Signal Value}

Stored Fault:

{None, Faulted}

Reference:

{Internal/External}

A Backup Converter in a 1:8 Switch Configuration will issue the following string of information:

Hot Converter:

{Identifies the Converter number with the highest priority
in reference to the Switch}

Frequency:

{Current Frequency}

Gain:

{Current Gain}

RSS:

{Text, Signal Value}

Stored Faults:

{None or Faulted}

One For Eight Switch Status:

{Indicates the status of each prime converter}

Switch is in:

{Manual Mode, Auto Mode}
Prime 1
Prime 2
Prime 3
Prime 3
Prime 4
Prime 5
Prime 6
Prime 7
Prime 8

Backup is:

{Available, Online for Converter [1…8]}

Notes: If none of the converters are faulted, the ‘Hot Converter’ will be the converter for
which the backup is in hot standby.

If one or more of the converters have faulted, the ‘Hot Converter’ will be the converter that
the backup is currently replacing.

If the status indicates that the backup is available, then the backup is not currently
replacing any of the primes.

4.5.7 Clear Faults Command (All)

The operator may wish to remotely clear any stored faults. Issue the following command:

@01/CLRFAULT<cr>

4.5.8 Auto Mode Command (P1:1, B1:1, B1:8)

This command allows the operator to put the switch back into Auto Mode. Issue the following
command:

@01/AUTO<cr>