Pub. 42004-486B

Model 352-7xx and 352-8xx Division 1 VoIP Page Phones – Wired & WiFi

Page 4 of 29

f:\standard ioms - current release\42004 instr. manuals\42004-486b.doc
12/14

Installation

Installation Guidelines

These enclosures must be installed by trained, qualified and competent personnel. Installation must
comply with state and national regulations, as well as safety practices for this type of equipment.

CAUTION

Do not install this equipment in hazardous areas other than those

indicated on the approval listing in the “Specifications” section of this manual. Such installation
may cause a safety hazard and consequent injury or property damage.

The mounting location must be flat and provide proper clearance, rigidity and strength to support the
enclosure and all contained devices.

WARNING

Securely fasten the enclosure to the mounting location, using 3/8-inch diameter

steel mounting bolts and washers, or washer head bolts.

WARNING

Do not disconnect equipment while energized.

Insure proper grounding to protective earthing.

WARNING

The front cover is not hinged to the rear enclosure. When the cover bolts

are removed, the cover must be adequately supported.

ATTENTION

Installation should be performed by qualified personnel and only in

accordance with the National Electrical Code or applicable local codes.

Inspect and clean the machined flange flame joint surfaces of both the cover and box. Surfaces must be
smooth, free of nicks, scratches, dirt or any foreign particle build-up that would prevent a proper seal.
Surfaces must seat fully against each other to provide a proper explosion-proof joint. Clean surfaces by
wiping with a clean lint-free cloth.

Apply a light coat of Killark “LUBG” lubricant to flange surfaces and close the cover. Install and tighten
all cover bolts to 30 ft-lbs. Make certain no cover bolts are omitted. Use only those bolts supplied with
the enclosure.

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:
Electrostatic Discharge (ESD) Protection: Your telephone has an earth ground terminal provision.

Ensure that it is connected to ground in accordance with all local safety regulations and the National
Electrical Code (NEC). Grounding must be ensured for safe and stable communications. Do not use
long and coiled ground wires. Trim ground wires to the required length. Please note proper
grounding does not eliminate the need for lightning protection for the telephone or the telephone
system.

 NEVER install the telephone during a lightning storm.
Install a Cat5 data line lightning surge protector on any phone installed where the phone or phone

cable is at risk of being exposed to lightning strikes. The lightning arrestor must be installed as close
to the phone as possible in a non-hazardous environment. The lightning arrestor must not be installed
within the telephone enclosure.