How to access atc mode information, Example of how to view last transaction, Definition/function of atc codes – Gasboy M06875K00X User Manual

Page 19: 100 programming code, 200 inspection mode, 300 view last transaction

Advertising
background image

MDE-4556 Gasboy ATC Kits M06875K00X Installation Manual • July 2006

Page 19

Programming the ATC Option

How To Access ATC Mode Information

Example of How To View Last Transaction

1

Enter 3-digit keypad code for information type desired
(see

Definition/Function of ATC Codes

below).

2

Press ENTER.

3

Press 1 for Meter Position One information.

4

Press ENTER.

5

Record the information.

6

Continue to press each position number for corresponding position information.

7

Press ENTER.

8

Press F2 to exit ATC Mode.
(Wait for 1-minute timeout if F2 is nonfunctional.)

Definition/Function of ATC Codes

100 Programming Code

Instructions for programming ATC option are given in

“How To Program Each Fueling

Position” on page 18

.

200 Inspection Mode

Access this mode to obtain a precise reading of ATC system operation during an actual
transaction. This is the most accurate means of checking ATC system accuracy because
temperature readings are displayed during transaction.
Pure product only: Program a blender for 100%, otherwise the PPU display shows error code
105-product error.

• Money display-shows uncompensated volume
• Volume display-shows compensated volume
• PPU display-shows real-time temperature (in degrees Celsius).

300 View Last Transaction

Access this mode after a transaction. This mode can be used as a basic check to make sure
ATC system is operating properly. Temperature displayed in this mode is an average during
the last transaction. Do not use this mode to verify the accuracy of ATC system.
There are no blender restrictions.

• Money display-shows uncompensated volume.
• Volume display-shows compensated volume.
• PPU display-shows average temperature (in degrees Celsius).