Programming the ATC Option
ATC Error Codes
The following list describes ATC error codes that you may observe. These codes are useful
when troubleshooting a problem.
Error Code
Error Displayed
Description
00
NO ERROR
No errors - no code displayed
100
PROGRAMMING ERROR
All fuel types not programmed
101
ROM CHECKSUM
Controller ROM checksum error
102
RAM ERROR
Controller RAM write/read error
103
T-METER DEAD
Not receiving any T-meter pulses
104
T-METER SYNC
Receiving T-meter pulses, but with errors
105
PRODUCT ERROR
Multiple product selected
106
RAMP RANGE ERROR
Gasboy use only
107
RANGE ERROR FOR PROBE Probe out of range
108
MISSING ERROR
Probe information missing
109
PULSER ERROR
Pulser fail
110
RESET JJ ERROR
Reset jump jack is installed
111
RAM CORRUPTED
RAM data corrupted
112
NO INPUT TIMER
No timer A interrupts occurring
113
NO OUTPUT TIMER
No timer B interrupts occuring
114
POWER FAIL ERROR
Power fail signal stuck
115
RECURSION ERROR
Read T-meter interrupt recursion