301 display volume correction factor (vcf), 302 display density, 303 display temperature – Gasboy M06875K00X User Manual

Page 20: 304 display gross volume totals, 500 software version, 600 troubleshoot probe, 601 probe history

Advertising
background image

Programming the ATC Option

Page 20

MDE-4556 Gasboy ATC Kits M06875K00X Installation Manual • July 2006

301 Display Volume Correction Factor (VCF)

• Money display-shows product number.
• PPU display- shows volume correction factor.

302 Display Density

PPU display-shows programmed density information for selected meter.

303 Display Temperature

PPU display-shows current product temperature for selected meter.

304 Display Gross Volume Totals

Volume and PPU displays-shows a 10-digit number representing the cumulative
uncompensated volume total of the selected meter for a pure product.

500 Software Version

Main display-shows software version number.

600 Troubleshoot Probe

Access this mode to troubleshoot probes. There should be a small change in readings every
second if T-Meter and controller board are working properly. Each probe can be checked by
entering meter number.

• Money display-pulse width in terms of counts
• Volume display-probe resistance in ohms
• PPU display-shows the temperature of probe (in degrees Celsius)

601 Probe History

Use this mode to display probe history since ATC was installed. This is useful for
troubleshooting intermittent probes or probe connections. Access each probe by entering
meter number.

• Money display-shows probe number entered
• Volume display-shows total number of probe range errors logged
• PPU display-shows total number of missing probe pulse errors