Caution – Gasboy 03908X User Manual

Page 23

Advertising
background image

MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006

Page 23

Installation

33

Using SAF-T-LOK TPS sealant, coat the BC407 Thermowell threads and thread into one of
the holes where the plugs were removed in the previous step (

Figure 22

).

Figure 22: Thermowell and Probe Assembly Connections

34

Using a proper size wrench, tighten the thermowell and place the 235-C Thermowell plug into
the thermowell.

35

Coat the threads of the BC546 Adapter with SAF-T-LOK TPS sealant and turn it into the other
hole where the plugs were removed in

step 32

(see

Figure 22

).

36

Coat the threads of the W199 Probe Assembly with SAF-T-LOK TPS sealant and turn it into
the BC546 adapter mounted in the previous step.

37

Using the proper size wrench, tighten both the adapter and probe.

When applying

SAF-T-LOK TPS sealant on threads, leave the two threads that enter the hole

first free of sealant to prevent the sealant from entering, and possibly damaging or inhibiting
proper operation of, the unit.

CAUTION

Probe Assembly

Thermowell Plug

Adapter

Thermowell

Be sure the threads on the thermowell, adapter, and probe assembly are properly
coated with the SAF-T-LOK TPS sealant and tightened properly to prevent leaks

.

CAUTION

Advertising