Gasboy CFN Series Site Controller III Start-up User Manual

Page 91

Advertising
background image

MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Page 85

Load Fuel Products, Pumps, Tanks, Prices, and Taxes

Start-up Commands

Load Fuel Products, Pumps, Tanks, Prices, and Taxes

To load the fuel products, pumps, tanks, prices and taxes, proceed as follows:

1

Type REM PRO;A to initialize all the product codes and clear any existing product
information for fuel and non-fuel products (

Figure 13-11

).

Note: Use the; A option at start-up only.

Figure 13-11: Example of REM PRO;A Command

P* REM PRO;A <RETURN>

P*

2

Type LO PRO;AC to load the system’s fuel product codes, categories, names, and pricing data
(

Figure 13-12

).

Figure 13-12: Example of LO PRO;AC Command with Prompts

P* LO PRO;AC <RETURN>

Product code? 1 <RETURN>

Category? 1 <RETURN>

Product name? Regular <RETURN>

Minimum price? 0 <RETURN>

Maximum price? 0 <RETURN>

Taxes? 0 <RETURN>

Product code? <RETURN>

P*

3

Type LO IN;C to load inventory amounts and reorder levels for fuel products (

Figure 13-13

).

Note: LO IN automatically enables inventory tracking. For more information on inventory

tracking, refer to MDE-4762 Site Controller III Manager’s Manual for Windows XP
Embedded.

Figure 13-13: Example of LO IN;C Command with Prompts

P* LO IN;C <RETURN>

Product? 1 <RETURN>

Quantity? 400 <RETURN>

Reorder level? 100 <RETURN>

P*

Advertising