Gasboy CFN Series Site Controller III Start-up User Manual
Page 92

Start-up Commands
Load Fuel Products, Pumps, Tanks, Prices, and Taxes
Page 86 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
4
Type RE PU to reset the pumps to zero (
).
If you wish to set the quantity and dollar totalizers maintained by the SC to the same settings
as the mechanical totalizers on the pump, do a LO PU;C command (
Note: You may load up to five hoses per pump. When you enter the last hose for a particular
pump, press RETURN at the next hose number prompt to get the next Pump Number
prompt.
Figure 13-14: Example of RE PU Command with Prompt
P* RE PU <RETURN>
Verify (Y/N)? Y <RETURN>
P*
Figure 13-15: Example of LO PU;C Command with Prompts
P* LO PU;C <RETURN>
Pump number? 1 <RETURN>
Hose number? 1 <RETURN>
Quantity? 5624.8 <RETURN>
$amount? 3217.95 <RETURN>
Hose number? <RETURN>
Pump number? 2 <RETURN>
Hose number? 2 <RETURN>
Quantity? 2345.9 <RETURN>
$amount? 6789.10 <RETURN>
Hose number? <RETURN>
Pump number? <RETURN>
P*
5
Type LO TA;C to load the system’s initial quantity, product code and reorder level for each
tank (tank inventory) (
Figure 13-16: Example of LO TA;C Command with Prompts
P* LO TA;C <RETURN>
Tank number? 1 <RETURN>
Quantity? 9325 <RETURN>
Product code? 1 <RETURN>
Reorder level? 2000 <RETURN>
Tank number? <RETURN>
P*