Start-up Commands

Load Fuel Products, Pumps, Tanks, Prices, and Taxes

Page 86 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

4

Type RE PU to reset the pumps to zero (

Figure 13-14

).

If you wish to set the quantity and dollar totalizers maintained by the SC to the same settings
as the mechanical totalizers on the pump, do a LO PU;C command (

Figure 13-15

).

Note: You may load up to five hoses per pump. When you enter the last hose for a particular

pump, press RETURN at the next hose number prompt to get the next Pump Number
prompt.

Figure 13-14: Example of RE PU Command with Prompt

P* RE PU <RETURN>

Verify (Y/N)? Y <RETURN>

P*

Figure 13-15: Example of LO PU;C Command with Prompts

P* LO PU;C <RETURN>

Pump number? 1 <RETURN>

Hose number? 1 <RETURN>

Quantity? 5624.8 <RETURN>

$amount? 3217.95 <RETURN>

Hose number? <RETURN>

Pump number? 2 <RETURN>

Hose number? 2 <RETURN>

Quantity? 2345.9 <RETURN>

$amount? 6789.10 <RETURN>

Hose number? <RETURN>

Pump number? <RETURN>

P*

5

Type LO TA;C to load the system’s initial quantity, product code and reorder level for each
tank (tank inventory) (

Figure 13-16

).

Figure 13-16: Example of LO TA;C Command with Prompts

P* LO TA;C <RETURN>

Tank number? 1 <RETURN>

Quantity? 9325 <RETURN>

Product code? 1 <RETURN>

Reorder level? 2000 <RETURN>

Tank number? <RETURN>

P*