2.10 CONNECTING TO WELDING ROBOT

Select which one of the KempArc Pulse TCS power sources you want to make the leading

unit that controls the first filler wire. In this unit you should install the fieldbus card, which

connects the KempArc Pulse TCS system to the robot control unit.
It is recommended to install the fieldbus card to the same power source unit, which is

connected to the KempCool 40 cooling unit.

To install the fieldbus card, do the following:

1.

Open the cover of the black control unit box located above the power source.

2.

Install the fieldbus card onto the interface card as shown in the picture. Attach the fixing

nuts.

3.

Connect the welding robot's fieldbus cable to the fieldbus card's connector.

4.

Close the cover of the black control unit box.

Fieldbus cable connector

Fixing nuts

Fieldbus card

Interface card