Kemppi Pulse TCS User Manual

Page 20

Advertising
background image

EN

3.4.3 Welding functions

OTHER PROCESSES

(In Edit Channel menu 3/6)

HotStart

ON, OFF or USER

Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF

HOTStartLevel

-50 ... +100 %

1 % steps. Factory setting 40 %

Hot 2T Time

0 – 9.9 s

0.1 s steps. Factory setting 1.2 s

CraterFill

ON, OFF, USER

Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF

CraterStart

10 – 250 %

Factory setting is 100%

Set the level of the curve where the crater
filling will start

CraterFillEnd

10 – 250 %
lower than start

1 % steps. Factory setting 30% Set the level of the curve where the crater

filling will end.

CraterTime

0.0 – 10.0 s

0.1 s steps. Factory setting 1.0 s CrateFill Slope Time

Creep Start

10 – 99 %

1% steps. OFF, CURVE
(OFF = 100%)

Factory setting is CURVE (Creep Start value
comes from Welding Curve).

StartPower

-9 ... +9

Factory setting is 0

Adjusts arc ignition

WISEROOT / WISETHIN

HotStart

ON, OFF or USER

Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF

HOTStartLevel

-50 ... +100 %

1 % steps. Factory setting 40 %

Hot 2T Time

0 – 9.9 s

0.1 s steps. Factory setting
1.2 s

CraterFill

ON, OFF, USER

Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF

CraterStart

10 – 250 %

Factory setting is 100%

Set the level of the curve where the crater
filling will start.

CraterFillEnd

10 – 250 %
lower than start

1 % steps. Factory setting 30%

CraterTime

0.0 – 10.0 s

0.1 s steps. Factory setting
1. 0 s

Creep Start

10 – 99 %

1% steps. OFF, CURVE
(OFF = 100%)

Factory setting is CURVE (Creep Start value
comes from Welding Curve).

18

KempA

rc P

ulse

TCS / © Kemppi O

y / 1204

Advertising