Kemppi Pulse TCS User Manual

Page 25

Advertising
background image

EN

4.

Gas test button

5.

Wire inch button

6.

Meter display for

a) welding voltage/plate thickness/timer settings

b) adjustment value of selected parameter

7.

Welding process indicators: MIG, 1-MIG, PULSE, DOUBLE PULSE, WISE*

8.

Control knob for setting values for

a) wire feed speed

b) welding power (Synergic 1-MIG and PULSE)

c) additional parameters (= Wire inch, Gas Test)

9.

Memory channels 0 – 99, programming through K 60 panel on the power source

10. Control knob for setting values for

a) welding voltage

b) welding arc length (Synergic 1-MIG and PULSE)

c) additional selected parameters (= MIG Dynamics)

11. Dual function button for

a) saving parameter adjustments

b) locking the control panel (long press)

12. Button for activating the Crater fill or Hot start functions

13. Indicators showing whether the welding parameters come from welding robot or

control panel

* Not included on standard delivery.

In normal MIG welding, the wire feed speed and welding voltage are adjusted separately.

Unlike the above, the 1-MIG and WiseRoot and WiseThin processes are synergetic welding

processes where the welding voltage and other welding parameters are interconnected so

that the welding power and arc length are adjusted to attain optimal welding values.

Automatic Weld Data display:

Last recorded welding values are displayed post welding. See power source panel K 60. Select

MENU and then Weld Data.

23

KempA

rc P

ulse

TCS / © Kemppi O

y / 1204

Advertising