Kemppi Pulse TCS User Manual

Page 18

Advertising
background image

EN

3.4.2 Welding parameters (Channel menu 2/6)

MIG

WFSpeed

0.7 – 25 m/min

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

Voltage

8 – 50V

0.1V steps

Controls the length of the arc

Dynamics

-9 ... +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

1-MIG

WFSpeed

0.7 – 25 m/min

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

FineTuning

Factory setting is 0
( = curve point)

Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits

FineTuningMax

0 – 9

0.5 steps

Set the limit for maximum arc length

FineTuningMin

-9 ... 0

0.5 steps

Set the limit for minimum arc length

Dynamics

-9 ... +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

PULSE MIG

WFSpeed

0.7 – 25 m/min

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

FineTuning

Factory setting is 0
( = curve point)

Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.

FineTuningMax

0 – 9

0.5 steps

Set the limit for maximum arc length

FineTuningMin

-9 ... 0

0.5 steps

Set the limit for minimum arc length

Dynamics

-9 ... +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Pulse Current

-10 ... +15 %

Factory Setting
is 0%

Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.

16

KempA

rc P

ulse

TCS / © Kemppi O

y / 1204

Advertising