Kemppi Pulse TCS User Manual

Page 19

Advertising
background image

EN

DOUBLE PULSE MIG

WFSpeed

0.7 – 25 m/min

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

FineTuning

Factory setting is 0
( = curve point)

Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.

FineTuningMax

0 – 9

0.5 steps

Set the limit for maximum arc length

FineTuningMin

-9 ... 0

0.5 steps

Set the limit for minimum arc length

Dynamics

-9 ... +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Pulse Current

-10 ... +15 %

Factory Setting
is 0%

Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%

DPulseAmp

0.1 – 3.0 m/min

Factory setting is
CURVE

Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding Curve.

DPulseFreq

0.4 – 8.0 Hz

Factory setting is
CURVE

Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding Curve.

WISEROOT / WISETHIN

)

WFSpeed

0.7 – 14 m/min

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

BaseCurrent

Adjusts the base current of the curve in certain limits. In
other words, it adjusts the “length of the arc” in certain
limits.

BaseCurrentMax

0 – 50 %

1% steps

Set the limit for maximum “arc length”

BaseCurrentMin

-50 ... 0 %

1% steps

Set the limit for minimum “arc length”

FormingPulse

Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.

FormingPulseMax

0 – 50 %

1% steps

Set the limit for maximum forming pulse current

FormingPulseMin

-50 ... 0 %

1% steps

Set the limit for minimum forming pulse current

StartTime

-9 ... +9

Factory setting is
CURVE

Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.

StartVoltage

Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.

17

KempA

rc P

ulse

TCS / © Kemppi O

y / 1204

Advertising