E24V3 QUICK TOUR

e24 Dimming System

Operator Manual V3.0

Page 10

LSC Lighting Systems (Aust) Pty. Ltd

GST18 Patch bay with 4 parallel dimmer outputs
plus 2 Hot-power outputs per channel

Export models can be supplied with or without
output patching. Export models with a patch bay
have two optional types of dimmer patch
connector.

• ST18 connector patch bays provide two

parallel dimmer outputs plus one Hot-
power per channel.

• GST18 connector patch bays provide

four parallel dimmer outputs plus two
Hot-power outputs per channel.

ST18 Patch bay with 2 parallel dimmer outputs
plus 1 Hot-power output per channel

Note: LSC Lighting System accepts no
responsibility for damage that may occur to
the connector, the dimmer or the load if the
patch connectors are disconnected whilst
under load.

3.7 Output Options

If you need to connect to different types of load
connectors, you can order multiple types of
output connector panels. The patch-cable/output
connector panel can be easily changed to a
different output connector type in less than 5
minutes.
The patch leads are hard-wired to the output
connectors and pass through the rear panel
arranged in the connector groups. This allows
quick identification of patch leads to output
connectors whilst patching.
Labelling of the output connectors is via alpha
characters. These letters appear next to each
connector and can be easily seen even when
mating connectors are fitted.
The patch leads are also labelled in accordance
with the output connector letter and the circuit
number for the connector.

For example, the patch lead for circuit for 4 on
connector F will be labelled “F4”.

Australian models have the following patch
cable to output connector wiring options;

48 GST18 patch cables wired to eight 19 pin

Socapex connectors (6 circuits each)
providing 48 outputs.

48 GST18 patch cables wired to twelve 10

pole Harting connectors (4 circuits each)
providing 48 outputs.

60 GST18 patch cables wired to twelve 10

pole Harting connectors (5 circuits each)
providing 60 outputs.

48 GST18 patch cables wired to eight 16

pole Harting connectors (6 circuits each)
providing 48 outputs.

48 patch cables wired to eight 19 pin Socapex
connectors labelled A thru H (6 circuits each)
providing 48 outputs

Export Patch models have the following patch
cable to output connector wiring options;

48 GST18 (or ST18) patch cables wired to

eight 19 pin Socapex connectors (6 circuits
each) providing 48 outputs.

48 GST18 (or ST18) patch cables wired to

eight 16 pole Harting connectors (6 circuits
each) providing 48 outputs.

64 GST18 (or ST18) patch cables wired to

eight 16 pole Harting connectors (8 circuits
each) providing 64 outputs.

48 patch cables wired to eight 16 pole Harting
connectors (6 circuits each) providing 48
outputs
.