(User Defined Settings Continued)

Idle Mode
Sets what the humidifier will do
during periods with no demand. Idle
Only = Do nothing. Idle Drain = Drain
the tank if there is no demand (wait
time set with idle Time parameter).
Keep Warm = periodically open CV
valve to keep tank warm. for a
demand and drain the tank if no
demand (Default = Idle Drain)
Idle Time
Sets the time without demand before
the Idle Drain function will drain the
tank (if activated). (Default = 72 hr)



Fill Correction
Increases or decreases the length of
fill valve pulses to compensate for
abnormal site conditions. (Default =
100%)

Drain Correction
Increases or decreases the length of
drains to compensate for abnormal
site conditions. (Default = 100%)


Float Check
Sets the time of day when a float
check to verify drains and float
operation will take place. Can also
disable the float check. (Default =
23:30 and On)


Date
Sets the date. Selecting Day, Month,
or year takes the user to a submenu
that allows the value to be increased
or decreased by pressing up/down
arrows. Set accepts the setting.


Idle Mode

: Idle Drain

Idle Mode
Idle Drain
Idle Only
Idle Drain
Keep Warm

Menu

Set

Idle Drain

Idle Time

: 72 hr

Idle Time
72 hr

72 hr

Menu

Set

72 hr

Fill Corr

: 100%

Fill Correction
100 %

100 %

Menu

Set

100 %

Drain Corr

: 100%

Drain Correction
100%

100 %

Menu

Set

100%

Float Ck

: 23:30

Float Ck
Hour

: 23

Minute

: 30

Status

: On

Menu

Set

Hour

: 23

Date

: 27/06/09

Date
Day

: 27

Month

: 06

Year

: 09

Menu

Set

Day

: 27