Chapter 5: System Alarms

Monitor Alarms

Alarms are brief text messages that appear on your workstation when the Call Relay 60 unit encoun-
ters a problem, such as a failed interface, disconnected call, etc. You can reach the Alarm Manager
via Command Line Interface (CLI) alarm monitoring system.

How to Read Alarms

The Alarm Manager reports alarms according to criteria such as the alarm’s severity level, type,
description, etc. There are two alarm types displayed: Active Alarms and Alarm History. An Active
Alarm list displays all the alarms still active on the system; these alarms have not been cleared or
deleted. An Alarm History is a list of the last 100 alarms stored in the system since the last time you
performed a delete operation.

Definitions for all generated alarm fields appear in Table 5-1.

Table 5-1 Alarm Fields and Definitions

Field

Definition

Valid Entry

IP #

The unit’s IP address (32 bit
address).

Example:192.168.1.34.

Sequence #

Internal number used to identify
alarms.

01, 02, 03, etc.

Type (displays only if you gener-
ate an Alarm History)

The type of alarm generated.

ALR = Alarm. This indicates an
active alarm.
CLR= Clear. This indicates an
alarm that has been cleared from
the system.
RPT= Report. This indicates that
the alarm has been generated for
a report. This entry is for internal
use only; if you see a report that
is causing problems, contact cus-
tomer service.

Severity

Level or alarm severity.

1 = Critical (complete system is
affected).
2 = Major (major problem is
detected).
3 = Minor (minor problem is
detected).
4 = Info (Information about a
minor problem).

Description

A text description of the alarm;
see Table 5-2 for detailed descrip-
tion.

Varies.