View alarms, Display all alarms, Display active alarms – Quintum Technologies Tenor Call Relay 60 User Manual

Page 50: View alarms -6, Display all alarms -6, Display active alarms -6

Advertising
background image

P/N 480-0076-00-00

5-6

Chapter 5: System Alarms

View Alarms

The Command Line Interface (CLI) enables you to view alarms through the Monitor mode. You can
view active alarms, as well as view an alarm history list.

Display all Alarms

You are able to display both active alarms and an alarm history as follows:

1. Through CLI, access the Monitor prompt.

2. Type alarm. Both active alarms and the alarm history will be displayed. See section

How to Read

Alarms

for field definitions.

Figure 5-1 Alarm sample

IP# Sequence# Type Severity Desc Slot# Device# Line# Channel# Date/Time

192.168.20.444:4:ALR:1:Call Handler not Registered with Gatekeeper:0:0:0:0:THU JAN 13 13:21:27 2005

192.168.20.444:5:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) register):0:0:0:0:THU JAN 13 13:21:27
2005

Display Active Alarms

1. Through CLI, access the Monitor prompt.

2. Type alarm a. The active alarms will be listed. See section

How to Read Alarms

for field defini-

tions. If you enter alarm without a command following it, both active alarms and the alarm his-
tory will be displayed.

Figure 5-2

IP# Sequence# Type Severity Desc Slot# Device# Line# Channel# Date/Time

192.168.20.444:10:CLR:3:Border Element connection lost:0:0:0:0:THU JAN 13 13:21:27 2005

Active Alarm Sample

Advertising