DIU 2130 Configuration

Before configuring a DIU 2130, verify that:

A data bus has been assigned to the CSU of the associated
NCC, SCC, or TAC. This bus conveys customer data between
the DIUs and the CSU during normal operation.

The proper DIU timing mode has also been selected on the
associated CSU.

Configuration

Options and

Default Settings

Table 1-1 provides the DIU 2130 configuration options and factory
default settings. These settings allow the DIU to interface properly
with the customer equipment and the associated CSU for T1
network transmission. The DIU 2130 is shipped with the default
settings listed in the table.

Table 3-1

DIU 2130 Configuration Options and Default Setting

Description

Options

Default

Setting

Data port speed

56 kbit/s to 1.536 Mbit/s in multiples of 56 or 64

kbit/s

--

Data mode = 64 kbit/s

Yes or No

No (56

kbit/s)

CA, RTS, or RS control lead

Yes = forced on,

No = follow DTE input

No

CD, DTR, or TR control lead

Yes = forced on,

No = follow DTE input

No

CB, CTS, or CS control lead

Yes = always on,

No = follow CA, RTS, or RS; turned off during alarm

No

CC, DSR, or DM control lead

Yes = always on,

No = follow CD, DTR, or TR; turned off during alarm

No

CF, RR, or RLSD control lead

Yes = always on,

No = follow CD, DTR, or TR; turned off during alarm

No

Data channel loopback enable

Yes or No

No

Timing Unit enable

Yes or No

No

Data equipment clock

TT, ST, or inverted ST (ST)

TT or ST