DIU 2130 Configuration

3-4

Verilink

The

S) shelf/slot

S) shelf/slot

S) shelf/slot

S) shelf/slot

command is used to navigate from one module to

another. Type S and press ENTER. The prompt for selecting another
module displays:

Enter shelf,slot >

Enter shelf,slot >

Enter shelf,slot >

Enter shelf,slot >
For this example the node has only one shelf (shelf #1) and the DIU
2130 is in slot two of that shelf. Enter 1,2 and press ENTER.

The prompt line returns as:

[1,2] DIU 2130 (UPDATE) >

[1,2] DIU 2130 (UPDATE) >

[1,2] DIU 2130 (UPDATE) >

[1,2] DIU 2130 (UPDATE) >
This indicates that the DIU 2130 has been selected. Type C and
press ENTER to select the DIU 2130 configuration menu.

NOTE: Whenever the word UPDATE appears in the command line

prompt, it indicates that some information has changed since

the screen was last refreshed. To refresh the screen with

current information, press

ENTER

ENTER

ENTER

ENTER by itself.

Configuration

Menu

There is a brief delay as the SCC module tries to communicate with
a CSU module in Shelf 0, Slot 0 since this is the default value for
CSU assignment in a new DIU 2130 module. An address of Shelf 0,
Slot 0 is not a valid address. Modules are shipped this way,
however, so that they may be added to a shelf without interfering
with any existing applications. An error message displays:

No response from csu[ 0,0 ]

No response from csu[ 0,0 ]

No response from csu[ 0,0 ]

No response from csu[ 0,0 ]
The error message, in this case, means that the DIU 2130 is new
and has never been assigned to any CSU module in any slot of any
shelf. Ignore this error message.

Then the DIU 2130 Configuration/Diagnostic Menu displays.