T1 Dial Backup Option Overview

Verilink

5-9

MANUAL/MANUAL

The port does not switch when any of the above conditions
occur.

Table 1 provides the default setting and range of parameter values
for the user-programmable options.

Monitoring Dial Backup Status

Using the AM2000, you can check in what state the DIU 2130/DBU
element is currently operating by selecting DIU 2130/DBU from the
Online Access/Status Element menu. The DIU 2130/DBU Status
window shown in Figure 7 appears. Notice the option Active Path,
which indicates whether Port 2 is currently active.

Table 1

DIU 2130/DBU Configuration Settings

Option

Default

Range of Values

Installed and operational?

No

Y, N

Save configuration to DIU?

No

Y, N

Enable alarm reporting?

No

Y, N

Connected CSU shelf #

0

1-4

Connected CSU plug #

0

1-13

Port 1 Channel Assignment

unassigned

1-24

Port 1 Backup Mode

Automatic

Manual, Automatic

Port 1 EQP Name

blank

16 characters

Port 1 EQP SER.

blank

16 characters

Port 1 EQP Interface

blank

16 characters

Port 1 EQP Speed

blank

16 characters

Port 1 DS0 mode

No

Y,N

Port 1 Enable Selected Loops?

Yes

Y, N

Port 1 Enable Scramble?

No

Y, N

Port 1 EQP-Clock

ST

ST, INV ST, TT

Port 1 Force DTR?

No

Y, N

Port 1 Force RTS?

No

Y, N

Port 1 Force DSR?

No

Y, N

Port 1 Force CTS?

No

Y, N

Port 1 Force DCD?

No

Y, N

Port 1 Detect DTE LOS?

No

No, RTS, DTR

Port 1 Enable as TIU?

No

Y, N