Table 3-11 – Verilink HDM 2182 (880-502925-001) Product Manual User Manual

Page 46

Advertising
background image

Standalone HDM 2182 Management

3-24

Verilink HDM 2182 User Manual

Table 3-11 Restore Manufacturing Default Config Menu Options

Command

Description

A

TX Diagnostic Alarms—Sets the transmission of diagnostic alarms to the manufacturing

defaults.

HDM > a

Set TX Diagnostic Alarms to Manufacturing Default? (Y/N) >y

TX Diagnostic Alarms value is set to Default.

System could be in Unknown State. Please REBOOT the board!!

D

Day Alert Thresholds—Sets the 24-hour day alert thresholds to the manufacturing defaults.

HDM > d

Set Day Alert Thresholds to Manufacturing Default? (Y/N) >y

Day Alert Thresholds value set to Default.

System could be in Unknown State. Please REBOOT the board!!

Q

Qrt. Hr. Alert Thresholds—Sets the quarter hour (15-minute) thresholds to the

manufacturing defaults.

HDM > q

Set Qrt. Hr. Alert Thresholds to Manufacturing Default? (Y/N) >y

Qrt. Hr. Alert Thresholds value set to Default.

System could be in Unknown State. Please REBOOT the board!!

P

DS3 Port Configuration—Sets the DS3 Port Configuration to the manufacturing defaults.

HDM > p

Set DS3 Port Configuration to Manufacturing Default? (Y/N) >y

DS3 Port Configuration value set to Default.

System could be in Unknown State. Please REBOOT the board!!

S

SNMP Configuration—Sets the SNMP Configuration to the manufacturing defaults.

HDM > s

Set SNMP Configuration to Manufacturing Default? (Y/N) >y

SNMP Configuration value set to Default.

System could be in Unknown State. Please REBOOT the board!!

H

HSSI Port A & B Configuration—This option sets the HSSI Ports A and B Configurations to

the manufacturing defaults.

HDM > h

Set HSSI Port A & B Configuration to Manufacturing Default? (Y/N) >y

HSSI Port A & B Configuration value is set to Default.

System could be in Unknown State. Please REBOOT the board!!

X

exit menu—Returns you to the

Main Menu

, Figure 3-1.