Remote end setup, Remote end setup -9, Table 4-6 – Verilink HDM 2182 (880-502925-001) Product Manual User Manual

Page 57

Advertising
background image

HDM 2182 Management: Using NCM 2000

Verilink HDM 2182 User Manual

4-9

Table 4-6

HSSI Port A Configuration Menu Commands

Remote End Setup

Selecting R from the Main Menu displays the Data Link Layer
Remote Configuration Menu. This option provides the ability to
configure key communication characteristics of a DS3 module

Command

Description

Options

I

Circuit ID—A label for the circuit on this HSSI port. You may use up to

18 characters for this field.

P

Port Status—When Configuration Mode (below) is Automatic, the Port

Status is an informational display. In Automatic mode the HSSI data

port is in service when DTR is presented by the DTE and it is out of

service when the DTE fails to assert DTR.

When Configuration Mode (below) is set to Manual, the Port Status

command becomes a toggle. If Mode = Manual and Port Status = OUT

OF SERVICE, then issuing the Port Status command will place the port

IN SERVICE, whether or not any DTE ispresent and whether or not it is

asserting DTR. Conversely, if Configuration Mode = Manual and the

Port Status = IN SERVICE, issuing the Port Status command will place

the port OUT OF SERVICE, stopping all user data.

Status command will place the port OUT OF SERVICE, stopping all user

data.

1) In Service

2) Out of Service

M

Configuration Mode—The Configuration Mode toggles between

Automatic and Manual each time the Configuration Mode Command is

issued.

When Configuration Mode is Automatic, the Port Status is an

informational display. In Automatic mode the HSSI data port is in

service when DTR is presented by the DTE and it is out of service when

the DTE fails to assert DTR.

When Configuration Mode is set to Manual, the Port Status command

becomes a toggle. If Mode = Manual and Port Status = OUT OF SERVICE,

then issuing the Port Status command will place the port IN SERVICE,

whether or not any DTE is present and is asserting DTR. Conversely, if

Configuration Mode = Manual and the Port Status = IN SERVICE, issuing

the Port Status command will place the port OUT OF SERVICE, stopping

all user data.

1) Manual

2) Automatic

D

HSSI Data Rate Mode—This option toggles between NE Only and Both

NE & FE. Determines whether data rate changes made at this end are

propagated to the remote DS3 module as well. Selecting BOTH NE and

FE is suggested.

1) NE Only

2) Both NE & FE

R

HSSI Data Rate—This option displays prompt which allows you to enter

a data rate within a range. The bandwidth that will be made available to

the DTE on the HSSI interface will be expressed in increments of

1.6 Mbit/s each. (21 x 1.6 = 33.6 Mbit/s).

A

Data Scramble—If enabled, the actual user data is modified in an

industry standard method. This feature has no bearing on encryption

or the security of user data. It was added to allow inter-operation of the

HDM 2182 with DS3 products from other manufacturers.

A

X

Exit this Screen—Returns you to the

HDM Configuration Menu

,

Figure 4-4.