Rear module, Rear module -4 – Verilink QUAD DATA (880-503319-001) Product Manual User Manual

Page 12

Advertising
background image

Overview

1-4

Verilink QUAD DATA User Manual

Normal Operation

The meaning of the various states is listed in

Table 1-1

.

Table 1-1 LED States

Local Port

The

LOCAL

port on the front of the QUAD DATA module is normally

not used. Configuration and maintenance of the QUAD DATA
module should be done by connecting to the

LOCAL

port of the

associated SCM 3000 controller module.

Rear Module

The rear connector module used with the QUAD DATA front module
is a DIM 3030 (DIM stands for Data Interface Module). See

Figure

1-2

.

Figure 1-2 DIM 3030 Rear Connector Module

Adapter Cables

The DIM 3030 rear connector module presents 4 mini D-Sub 26-pin
connectors for the data ports. Depending on which electrical
interface type and data port mode is selected in the QUAD DATA
Configuration Menu, an appropriate adapter cable must be used.
The adapter cables all have a mini D-Sub 26-pin connector at one
end and the typical connector for the selected electrical interface at
the other end.

If the data port mode is DCE, use one of the adapter cables in

Table

1-2

.

State

Meaning

Not Lit

The port is not in service. Use the QUAD DATA

Configuration Menu (

Figure 3-2

) to place the port in

service. If no LEDs are lit, the module has no power.

Solid Green

Normal operation. There are no alarms, no loopbacks, and

the port is in service.

Solid Red

Loss of Signal detection is enabled and the port detects that

DTR is not asserted.

Solid Amber

A Data Port Loopback is active on the port.

Blinking

Amber to Red

The QUAD DATA module is sending a test pattern and

receiving errors.

DATA PORT 1

DATA PORT 2

DATA PORT 3

DATA PORT 4

DIM

3030