Quick Set-Up
2-2
Verilink QUAD DATA User Manual
illustrates the shelf configuration for this example.
Figure 2-1 Example Configuration
Log In
Connect a Craft cable to the port labelled
LOCAL
on the front of the
SCM module.
Connect the other end of the Craft cable to your PC or terminal. If
using a PC, start a session in a terminal program.
1. Set your terminal parameters to:
•
19.2 kbit/s
•
8 data bits
•
No parity
•
One stop bit
•
No flow control
2. Press E
NTER
.
3. The prompt
pSH+>
pSH+>
pSH+>
pSH+> appears.
4. Type “craft” (use lowercase)
5. The prompt
Your Password
Your Password
Your Password
Your Password appears.