Connect dte, Connect dte -8 – Verilink QUAD DATA (880-503319-001) Product Manual User Manual

Page 22

Advertising
background image

Quick Set-Up

2-8

Verilink QUAD DATA User Manual

4. The destination of circuit 2 is still the M1-3 multiplexer. The

value for DP is already correct. Use the DT command to select
virtual T1 number 5 of the 28 T1 circuits available in the M1-3
mux.

5. Type “DM” to change the destination port DS0 mapping. Set it

to shelf 1, slot 2, DSOs 1 through 12.

6. The settings for circuit type, priority, mode, and bus are

already correct. Type “S” to setup the circuit. A message
should appear

Successful Circuit Build

Successful Circuit Build

Successful Circuit Build

Successful Circuit Build. Exit to the Circuit

Manager Menu with the X command.

Cloning Circuit 3

1. Type “E” to begin. Input “QUADDATA_P1” at the circuit name

prompt. The Edit Circuit Menu appears.

2. Type “N” to change the name. Enter “QUADDATA_P3”. The

menu is redrawn with all of the source and destination port
values of the original circuit, but the status is shown as
inactive.

3. Type “SP” to change the Source Port. Set it to shelf 1, slot 3,

data port 3. (Port 3 of the QUAD DATA module).

4. The destination of circuit 1 is the M1-3 multiplexer, whereas

circuit 3 of this example uses a QUAD T1 module in slot 4 for
the destination. Use the DP command to select shelf 1, slot 4,
network port 1. The DT command disappears because the new
destination module does not map multiple T1 circuits to a
single network port.

5. Type “DM” to change the destination port DS0 mapping. Set it

DSOs 1 through 24.

6. The settings for mode, and bus are already correct. Type “S” to

setup the circuit. A message should appear

Successful Circuit

Successful Circuit

Successful Circuit

Successful Circuit

Build

Build

Build

Build.

Exit to the Circuit Manager Menu with the X command. Use X again
to return to the Main Menu.

Connect DTE

The DIM 3030 rear connector module is used with the QUAD DATA
front module. It has four mini D-sub 26-pin connectors.

Connect a (P/N 458-501594-001) V.35 adapter cable to data port 1
on the DIM 3030, connect the router to the Winchester 34-pin
connector.

Connect an (P/N 458-502045-001) EIA 530 adapter cable to port 2
for the video codec.

Use a (P/N 458-502059-001) RS-449 adapter cable on port 3 for the
mainframe channel extension.

Advertising