Building circuits, Building circuits -10 – Verilink QUAD DATA (880-503319-001) Product Manual User Manual

Page 34

Advertising
background image

Configuration

3-10

Verilink QUAD DATA User Manual

Table 3-4

Timing Menu Options

Building Circuits

When all of the ports on the QUAD DATA module have been
configured, use the Circuit Manager function of the SCM to build
circuits from the QUAD DATA module to the desired network
interface modules.

Since the Circuit Manager is a function of the SCM, it is covered in
detail in the

SCM User Manual

.

A brief discussion of building circuits can be found in the section

Building Circuits

” in Chapter 2 of this manual.

Menu

Option

Description

Instructions

PC)

The slot number of the application module which will be the

primary clock source for this shelf. This module will provide the

clock signal used to drive the transmit clock circuitry for all

modules in the shelf that use T1 rate clocks.

At the prompt, type the slot

number of the module

selected as the primary clock

source.

PS)

Clock source within the module selected for the PC option.

Select from the list of ports

available on the module.

PA)

Enables or disables fallback to primary clock source after a failed

condition has cleared. If disabled, the SCM never reverts to the

primary clock source until an operator changes this option.

Set to “Yes” if the node is to

revert to a timimg source

which failed, but is now OK.

SC)

The slot number of the application module which will be the

secondary clock source for this shelf. If the primary clock source

fails, this module will provide the clock signal used to drive the

transmit clock circuitry for all of the cards in the shelf which use

T1 rate clocks.

At the prompt, type the slot

number of the module

selected as the secondary

clock source.

SS)

Clock source within the module selected for the SC option.

Select from the list of ports

available on the module.

SA)

Enables or disables fallback to secondary clock source after a

failed condition has cleared. If disabled, the SCM never reverts to

the secondary clock source until an operator changes this option.

Set to “Yes” if the node is to

revert to a timimg source

which failed, but is now OK.

TC)

The slot number of the application module which will be the

tertiary (third) clock source for this shelf. If both the primary and

secondary clock sources fail, this module will provide the clock

signal used to drive the transmit clock circuitry for all of the cards

in the shelf which use T1 rate clocks.

At the prompt, type the slot

number of the module

selected as the secondary

clock source.

TS)

Clock source within the module selected for the TC option.

Select from the list of ports

available on the module.

TA)

Enables or disables fallback to tertiary clock source after a failed

condition has cleared. If disabled, the SCM never reverts to the

tertiary clock source until an operator changes this option.

Set to “Yes” if the node is to

revert to a timimg source

which failed, but is now OK.

X)

Returns to the

QUAD DATA Configuration Menu

.

Exits the

Timing Menu.