TROUBLESHOOTING

4.1

Power-up and Normal Operation

When power is initially connected to the 455U-D module, the module will perform internal
diagnostics to check its functions. The following table details the status of the indicating
LEDs on the front panel under normal operating conditions.

LED Indicator

Condition

Meaning

OK

Green

Normal Operation

Off

Power Disconnected or Battery Over-voltage

Red

Low Supply voltage or Internal Module fault

Radio RX

Green flash

Radio receiving data

Red flash

Weak radio signal

Radio TX

Flash

Radio Transmitting

RS232

Yellow flash†

RS232 Serial Port Activity (Older version Hardware) †

Orange flash

RS-232 port receiving and transmitting simultaneously

Red flash

RS232 serial port transmitting data to host device

Green flash

RS232 serial port receiving data from host device

RS485

Yellow flash†

RS485 Serial Port Activity (Older version Hardware) †

Orange flash

RS-485 port receiving and transmitting

Red flash

RS485 serial port transmitting data to host device

Green flash

RS485 serial port receiving data from host device

DCD

Green

Modem is Online and ready to send data.

Red

Modem is Online but Currently in Command Mode

Off

Communications failure or data connection not established

† Hardware version 1.5 and later has extended LED functionality, providing red & green
indication on the serial LEDs. Earlier hardware support single-color (yellow) serial LEDs.