Appendix C

S-Registers

Man_455U-D Rev 3.04

Page 81

Appendix C

S-Registers

The following table lists the S-Registers supported by the 455U-D modem.

No. Range Function

Comment

S0 0-255

Attempts

before

Answering Call

Should normally be set to 1. 0 disables auto
answering of calls (ATA command to answer calls
only).

S1 3-255

Escape

Sequence

Guard Time

Units 20 milliseconds. Min. Delay before and after
entering the escape sequence (“+++”) also Max.
Delay between characters of the escape sequence.

S2 1-255

Escape

Sequence

Character

Normally 43 = “+”

S3 0-127

Carriage

Return

Character

Normally 13 = <CR>

S4

0-127 Line Feed Character

Normally 10 = <LF>

S5

0-127 Back Space Character

Normally 8 = <BS>

S6

0-255 Inactivity Timer /

Link Check Timer

Units Seconds. 0 disables. How frequently to send a
“Link Check” message. Usually set less than the
timeout set by the AT\T command. Default 0.

S7

1-255 Number of Connection

attempts
(Acknowledged Mode)

How many times to attempt a connection after an
ATD command. Default 5.

S8

0-255 Test Timer

Units Seconds – How long to run tests (AT&Tx)

S9

0-255 Modem Receive Level Units (-)dBm – RSSI indication of last received

message. AT&T5 command may be more useful.

S10 0-255 DTR Loss Detection

Time

Units 10 milliseconds (Not Implemented)

S11 0-255 Change Over Delay

Time or Dual
Redundant Timeout

The trigger condition must be present for the time
period for the changeover to occur. Minimum time
period is 5 seconds

S12 read-

only

Command Mode
Diagnostic

Reason modem last returned to command mode, i.e.
connection lost.

S12 = 0 Reset (ATZ or Power Up).

S12 = 1 Escape sequence (“+++”)

S12 = 2 DTR lowered.

S12 = 3 No ACK from remote modem after connected.

S12 = 4 Activity timer timed out.