ATL Telecom R1-SW Ethernet Switch User Manual

Page 164

Advertising
background image

R1-SW24L2B User’s Manual

8-30

[alarm]

index status

sample

----- -------------- -----------------------------

1

valid

etherStatsPkts.1

[event]

index status type

----- -------------- ---------------

10

valid

logandtrap

.

.

#


Before configure RMON alarm group, you should verify that the statistics group
(<StatisticsIndex>) is defined. If you specify undefined statistics group, the ‘Can't fetch

the MIB values

’ message will be displayed:

(config)# rmon alarm 2 20 pkts 10 absolute rising threshold 1000 100 event-

index 1 1 owner kimka

Can't fetch the MIB values

(config)#


To display the detail information on an alarm group, enter the show rmon alarm command
with the alarm number:

# show rmon alarm 1

Alarm 1 is valid, owned by aaa

Monitors etherStatsEntry.etherStatsPkts.1 every 10 seconds

Taking absolute samples, last value was 0

Rising threshold is 1000, assigned to event 1

Falling threshold is 100, assigned to event 1

On startup enable rising or falling alarm

#


To delete a RMON alarm group, enter the no rmon alarm command in Global configuration
mode:

(config)# no rmon alarm 1

(config)#