Power supply indicators, Reference indicator – Grass Valley K2 Summit 3G v.9.0 User Manual
Page 36

Power supply indicators
Each power supply has LEDs that indicates status.
OK
~AC
Fault
Interpret the power supply LEDs as follows:
Status Condition
LED state
LED
The power supply is operating normally.
Green On
OK
There is a power supply fault.
Yellow On
Fault
The electrical current available to the power
supply meets power supply requirements. Input
> 85 VAC.
Green On
~AC
Another indicator of power supply operation is the audible fan noise. If a power cable is connected
to either power supply, the fan should stay on continuously on both power supplies. This is the case
even if the K2 Summit 3G system is shut down or restarting via the standby switch or the Windows
operating system.
The Service LED on the front of the K2 Summit 3G system also indicates power supply status.
If the power source and the power cord are OK yet there is still a power supply problem, the status
lights on the power supply indicate the problem.
Related Topics
on page 34
on page 81
Reference indicator
There is a small hole in the carrier module next to the “REF. LOOP THROUGH” BNC connectors.
Reference
Through this hole a LED is visible. When the LED is lit, the reference signal is present and locked.
36
K2 Summit 3G Service Manual
14 November 2012
Product description