Power supply indicators

Each power supply has LEDs that indicates status.

OK

~AC

Fault

Interpret the power supply LEDs as follows:

Status Condition

LED state

LED

The power supply is operating normally.

Green On

OK

There is a power supply fault.

Yellow On

Fault

The electrical current available to the power
supply meets power supply requirements. Input
> 85 VAC.

Green On

~AC

Another indicator of power supply operation is the audible fan noise. If a power cable is connected
to either power supply, the fan should stay on continuously on both power supplies. This is the case
even if the K2 Summit 3G system is shut down or restarting via the standby switch or the Windows
operating system.

The Service LED on the front of the K2 Summit 3G system also indicates power supply status.

If the power source and the power cord are OK yet there is still a power supply problem, the status
lights on the power supply indicate the problem.

Related Topics

Service LED

on page 34

Power supply problems

on page 81

Reference indicator

There is a small hole in the carrier module next to the “REF. LOOP THROUGH” BNC connectors.

Reference

Through this hole a LED is visible. When the LED is lit, the reference signal is present and locked.