Installing the ATTO Fibre Channel card driver

If the K2 Summit 3G system is on a redundant K2 SAN or is connected to direct-connect storage,
make sure that MPIO software is installed.

If your K2 Summit 3G system has the optional Fibre Channel card, the driver for the Fibre Channel
card is not installed on the recovery image provided by Grass Valley for that K2 Summit 3G system.
Therefore, after restoring the image, you must install the Fibre Channel card driver.

1. Open Device Manager.

2. Right-click on

K2 Summit Client

and select

Manage.

3. Click

Device Manager

4. Install the first Fibre Channel driver as follows:

a) Right click on the upper Fibre Channel Controller and select

Update Driver…

b) On the Welcome page, select

No, not this time

and then click

Next

.

c) Select

Install from a list or specific location

and then click

Next

.

d) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers\x86

.

e) Click

OK

.

f) Click

Next

.

g) Click

Finish

when prompted.

h) In the Found new hardware wizard that will open for the ATTO Phantom device, select

No,

not this time

.

i) Select

Install from a list or specific location

and then click

Next

.

j) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers

and select the

x86

directory if

installing on a 32-bit computer or the

x64

directory if installing on a 64-bit computer.

k) Click

OK

.

l) Click

Next.

.

m) Click

Finish

when prompted.

5. Repeat the process for the second Fibre Channel Controller as follows:

a) Right-click on the remaining Fibre Channel Controller and select

Update Driver…

b) On the Welcome page, select

No, not this time

and then click

Next

.

c) Select

Install from a list or specific location

and then click

Next

.

d) Browse to

C:\Profile\Drivers\ Atto 8Gb HBA Drivers

and select the

x86

directory if

installing on a 32-bit computer or the

x64

directory if installing on a 64-bit computer..

e) Click

OK

.

f) Click

Next

.

g) Click

Finish

when prompted.

6. Verify that the two "ATTO" devices are now listed under the SCSI and RAID Controllers

7. Close the Device Manager and System windows