background image

Corrective Actions

Possible Causes

Problem

Check network connections and
configuration. Check available storage on
the destination K2 Summit 3G system. In
Recorder, select the Time Dome and choose

Available Storage

. If the Time Dome is filled

it confirms that the destination K2 Summit
3G system is out of space. Make space on
the media drives by deleting unused clips and
emptying the Recycle Bin.

There is a network
connection error or the
media disks at the
destination are
reaching maximum
capacity.

When streaming to another
K2 Summit 3G system the
operation fails. In Transfer
Monitor the streaming
operation shows
“Status:Error”.

Use the Storage Utility to check the file
system.

Extended record/play
activity has
fragmented the disks.

System status message “File
system…is fragmented”.

Related Topics

Replacing a RAID 1 drive

on page 48

Checking the storage system

The following section provides guidelines for investigating problem areas related to the storage
system. Use this section if you have problems with media input and/or output that are intermittent
or seem to be related to certain usage patterns.

14 November 2012

K2 Summit 3G Service Manual

87

Troubleshooting problems