Front panel cable assembly, Led cable, Emi foam gasket – Grass Valley Profile Mix Effects Upgrad 100 Fibre Channel User Manual

Page 19: Fibre channel cable

Advertising
background image

Front Panel Cable Assembly

PDR 100 Fibre Channel Installation

19

Front Panel Cable Assembly

This is a replacement cable with an attached ferrite bead to insure that your Profile
system remains EMI compliant. Replacement of this cable is only necessary on
Profile systems with serial numbers lower than B041685.

LED Cable

This is a replacement cable with an attached ferrite bead to insure that your Profile
system remains EMI compliant. Replacement of this cable is only necessary on
Profile systems with serial numbers lower than B041685.

EMI Foam Gasket

This is EMI foam gasket is installed to insure that your Profile system remains EMI
compliant. Installation of this gasket is only necessary on Profile systems with
serial numbers lower than B041685.

Fibre Channel Cable

The cable connecting the Profile system to a Hub is a 5 meter, copper wire cable
with a DB-9 connector on each end. Note that other lengths of cable are available
from your Grass Valley Group representative. Also note that for distances greater
than 25 meters, quality will begin to deteriorate and a fiber-optic cable with
copper-to-fiber adapters is then recommended.

NOTE: Minimum cable distances should be used to reduce signal degradation
and error rates.

Advertising