PDR 100 Fibre Channel Installation

60

PDR 100 Fibre Channel Installation

Installing the PCI Interconnect Board

The PCI Interconnect board has three connectors which attach to edge-board
contacts on the Slave EDR, the Master EDR, and the Fibre Channel boards. See
Figure 20.

Figure 20. PCI Interconnection Board

The PCI board connectors are keyed to ensure correct orientation and the bottom
of the board identifies the connectors as J1, J2, and J3. J2 is further identified as
MASTER. To install the PCI board, refer to Figure 21 and proceed as follows:

1. Hold the PCI with the connectors pointing down and the connector

identifications towards the rear of the Profile chassis.

2. Align the PCI connectors so that J1 is over the Slave EDR header connector,

Master J2 over the Master EDR header connector, and J3 over the Fibre
Channel header connector, and the connector keys are over the index notches
on the boards.

9674-15

Master

J1

J2

J3

Index Notch