Power Supply

PDR 200 Service Manual

6-43

To install the power supply:

1. Position the power supply in the Profile chassis on the right side and slide towards the

rear panel until the holes in the chassis align with the power supply screw holes.

2. Use the Torx tool with the T10 tip to attach the power supply to the side of the chassis

with the screws previously removed (Figure 6-28, page 6-42).

3. Reconnect the two white connectors to the SCSI Backplane (page 6-16).

4. Reconnect all other previously removed cables to the power supply (Figure 6-27, page

6-41).

5. Use the torx tool with the T15 tip to connect power supply cables to the Motherboard.

6. Being careful to not crimp or damage cabling, use the Torx tool with the T10 tip to

install the power supply shield with the screw previously removed (Figure 6-26).

7. Noting the positions they were removed from and observing the disk handling

cautions, reinstall the disk drive caddies A3 and A4 (page 6-14).

8. Perform the fan tray installation procedure (page 6-18).

9. Reinstall the RS-422 Board in slot J17 (page 6-34).

10.Reinstall the board retainer brackets (page 6-32).

11.Reinstall the SCSI cable hold-downs.

12.Replace the covers (page 6-8) and reinstall the Profile chassis in the rack (page 6-7).

13.Reconnect the power cord and turn PDR200 power On.