Grass Valley Trinix NXT v.3.3.1 User Manual

Page 417

Advertising
background image

Trinix NXT — Installation and Service Manual

417

Trinix Fiber Boards Overview

WARNING

Fiber-optic connectors need to be cleaned every time they are mated and
un-mated; it is essential that fiber-optic users develop the necessary dis-
cipline to always clean the connectors before they are mated.

Follow these steps when cleaning fiber-optic connectors:

•

When cleaning the connector sections, include the tips and sides of fer-
rules, the interior walls of alignment sleeves, and the interior and exte-
rior of connector shells.

•

For plugs, the interior surfaces of alignment sleeves and the tips of
ferrules are to be cleaned with a cleaning stick treated with the
appropriate fluid. (Cleaning sticks with a slender design are avail-
able that allow alignment sleeves to be cleaned without having to
detach them.)

•

For jacks, it is important to clean both the tips and sides of the com-
pletely protruding ferrules.

•

Clean both the insides and outsides of the male and female connector,
as the shells tend to attract dust and metal particles.

•

The fiber end face and ferrule must be absolutely clean before it is
inserted into a transmitter or receiver.

•

Mate the connector immediately! Do not let the connector collect dust
before connecting.

•

Air can be used to remove lint or loose dust from the port of a trans-
mitter or receiver to be mated with the connector. Never insert any
liquid into the ports.

The Trinix Fiber modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless otherwise directed by Customer Service.

Power-up Diagnostics Failure

If the module has not passed self-diagnostics, do not attempt to trouble-
shoot. Return the unit to Grass Valley.

Troubleshooting

Electronic Circuit Breaker

: The electronic circuit breaker works during a

fault condition or an over-current that stops the module.

Remove the module and replace it in the frame. If the problem persists,
please refer to the Grass Valley Customer Service.

Module Repair

: If the module is still not operating correctly, replace it with

a known good spare and return the faulty module to a designated Grass
Valley repair depot. Call your Grass Valley representative for depot loca-