Checking and changing q parameters 9.6 – HEIDENHAIN TNC 320 (77185x-01) ISO programming User Manual
Page 257

Checking and changing Q parameters
9.6
9
TNC 320 | User's Manual for DIN/ISO Programming | 3/2014
257
You can have the Q parameters be shown in the additional status
display in the Manual, El. Handwheel, Single Block, Full Sequence
and Test Run operating modes.
If you are in a program run, interrupt it if required (for example,
by pressing the machine STOP button and the
INTERNAL STOP
soft key). If you are in a test run, interrupt it.
Call the soft-key row for screen layout
Select the layout option for the additional status
display: In the right half of the screen, the TNC
shows the
Overview status form
Press the
STATUS OF Q PARAM. soft key
Press the
Q PARAMETER LIST soft key
The TNC opens a pop-up window in which you
can enter the desired range for display of the
Q parameters or string parameters. Multiple Q
parameters are entered separated by commas
(e.g. Q 1,2,3,4). To define display ranges, enter a
hyphen (e.g. Q 10-14).