7 optional block skip, Application, Inserting the "/" character – HEIDENHAIN TNC 320 (77185x-01) ISO programming User Manual
Page 463: Erasing the "/" character, Optional block skip, Optional block skip 15.7

Optional block skip 15.7
15
TNC 320 | User's Manual for DIN/ISO Programming | 3/2014
463
15.7
Optional block skip
Application
In a test run or program run, the control can skip over blocks that
begin with a slash "/":
To run or test the program without the blocks
preceded by a slash, set the soft key to
ON
To run or test the program with the blocks
preceded by a slash, set the soft key to
OFF
This function does not work for
TOOL DEF blocks.
After a power interruption the TNC returns to the
most recently selected setting.
Inserting the "/" character
In the
Programming mode you select the block in which the
character is to be inserted
Select the INSERT soft key
Erasing the "/" character
In the
Programming mode you select the block in which the
character is to be deleted
Select the REMOVE soft key