6 Electrical Connection
SMA Solar Technology AG
✖ Is the stranded wire not visible in the chamber?
The cable is not correctly in place.
• Remove the cable and go back to step 2.
• Release the clamping bracket. To do so,
insert a screwdriver (blade width: 3.5 mm)
into the clamping bracket and lever it open.
4. Push the swivel nut up to the thread and tighten
(torque: 2 Nm).
+