12 Technical Data

According to IEC 60721-3-4, Installation Type C, Class 4K4H

According to IEC 60721-3-4, Transport Type E, Class 2K3

12.3 Protective Devices

DC reverse polarity protection

Short-circuit diode

DC disconnect device

Electronic Solar Switch

DC overvoltage protection

Thermally monitored varistors

AC short-circuit current capability

Current control

Grid monitoring

SMA Grid Guard 2.1

Maximum permissible fuse protection

80 A

Earth-fault monitoring

Insulation monitoring: Riso > 280 k Ω

All-pole sensitive residual-current monitoring unit

Available

12.4 Approvals

Country standard,
as per 11/2012

SMC 9000TLRP-10

SMC 10000TLRP-10 SMC 11000TLRP-10

VDE 0126-1-1

VDE-AR-N 4105

UTE C15-712-1

C10/C11

PPDS

RD 1663

RD 661

EN 50438

*

* EN 50438: Does not apply to all national variations of the standard.

GBT19939-2005

CGC GF001-2009

12.5 Climatic Conditions

Extended temperature range

− 25°C … +60°C

Extended humidity range

0% … 100%

Extended air pressure range

70.0 kPa … 106 kPa

Temperature range

− 25°C … +70°C