6.3 Determining free NetID

PV systems with SMA Bluetooth operating in close proximity to one another are distinguished by their
individual NetID. All devices in a PV system must have the same NetID. The NetID can be a number
from 1 to 9 or a letter from A to F. NetID 1 is not possible for Sunny Beam.
A free NetID is a NetID that is used by no other PV system with SMA Bluetooth in your vicinity.
Commission the Sunny Beam as described in section 6.4 . During the commissioning process, you
will receive instructions on how to detect a free NetID.

Overview of the NetIDs and their functions
NetID 0 and NetID 1 have special functions. Sunny Beam cannot detect any devices with the
NetID set to 1.

NetID

Function

0

Bluetooth is switched off.

1
(Status upon delivery)

Bluetooth is switched on.
The inverter or the SMA Bluetooth Repeater can only connect to a
maximum of 2 computers with Sunny Explorer from SMA Solar Technology
AG. A connection to the Sunny Beam is not possible.

2 to 9 and A to F

Bluetooth is switched on.
The inverter or the SMA Bluetooth Repeater can interlink with all SMA
Bluetooth products with the same NetID.