8 Object Dictionary

16

YASKAWA ELECTRIC

SIEP C730600 45B 1000-Series Option SI-S3 Technical Manual

Drives and Motion Profile Objects (DSP 402)

The drive supports the Drive and Motion Profile DSP 402 Velocity Mode. Before using the Velocity Mode objects the following parameters have to

be set up in the drive:

• The motor pole number must be set up in E2-04.

• The frequency reference and output frequency display unit has to be set to min

-1

by setting parameter o1-03 = 2.

If these settings are not done properly, the Velocity Mode objects cannot be used or deliver wrong data.

Communication Profile Objects (DS 301)

1000 (Hex) - Device Type

This object describes the type of device and its functionality. It is composed of a first 16 bit field that describes the device profile used and a second

16 bit field that gives additional information regarding optional functionality.

1001 (Hex) - Error Register

This register shows the fault status of the device. If any errors occurs in the device bit 0 (generic error) is set to one.

Output

2100

Drive Status

22

2101

<1>

Drive Status (Change of State filter support)

22

2110

Output Frequency

22

2111

<1>

Output Frequency (Change of State filter support)

22

2120

Output Current

23

2121

<1>

Output Current (Change of State filter support)

23

2130

Output Torque

23

2131

<1>

Output Torque (Change of State filter support)

23

2140

MEMOBUS/Modbus Read Command Response

23

2150

MEMOBUS/Modbus Write Command Response

23

2155

<1>

PDO Parameter Write Response

23

2160

MEMOBUS/Modbus Not Limited Enter Command Response

23

2180

<1>

Freely selectable (default: Input terminal status)

24

2190

<1>

Freely selectable (default: Analog input 1 monitor)

24

21A0

<1>

Freely selectable (default: none)

24

21B0

<1>

Freely selectable (default: none)

24

21C0

<1>

Freely selectable (default: none)

24

21D0

<1>

Freely selectable (default: none)

24

21E0

<1>

Freely selectable (default: none)

24

21F0

<1>

Freely selectable (default: none)

24

2200

Motor Speed

<2>

24

2201

<1>

Motor Speed (Change of State filter support)

<2>

24

<1> Available in option card software version 3102 and later.

<2> Units for motor speed are determined by o1-03. If the control mode for the drive is set to V/f control (A1-02=0) and V/f control with simple PG feedback is disabled (H6-01

≠3), then the

motor speed will be 0.

Object Type

<1> YASKAWA specifies this object as the drive digital output monitor. (Input from the network)

<2> YASKAWA specifies this object as the drive digital inputs. (Output to the network)

Index (Hex)

Name

Page

Common Entries

60FD

Digital Inputs

<1>

26

60FE

Digital Outputs

<2>

26

Device Control

6040

Controlword

24

6041

Statusword

25

6061

Modes of operation display

26

Velocity Mode

6042

vl target velocity

25

6043

vl velocity demand

25

6044

vl control effort

25

6046

vl velocity min max amount

25

6048

vl velocity acceleration

25

6049

vl velocity deceleration

25

604A

vl velocity quick stop

25

604C

vl dimension factor

25

604D

vl pole number

26

Index (Hex)

Subindex

Content

Access

PDO Mapping

Value Range

1000

Device type

Read Only

No

Unsigned 32

Index (Hex)

Subindex

Content

Access

PDO Mapping

Value Range

1001

Error register

Read Only

Possible

Unsigned 8

Index (Hex)

Content