7 Transmission Interface

YASKAWA ELECTRIC

SIEP C730600 50A YASKAWA AC Drive-Option Card MECHATROLINK-II Technical Manual

15

7

Transmission Interface

‹

MECHATROLINK-II Cyclic Transmissions

As a MECHATROLINK-I/MECHATROLINK-II station, the SI-T3 exchanges control data and I/O data with a control
device, such as a controller. Communications with the master are executed by sending response data timed to the
reception of command data for the local station address from the master in each transmission cycle. The formats for the
command and response data follow the specifications for the MECHATROLINK Drive commands.

‹

Basic Format of Data Transfer

The basic format for transferring data is as follows.

The size of the header for a data link layer is fixed at two bytes.

By setting, either 17 bytes (17-byte data transmission) or 32 bytes (32-byte data transmission) can be selected as the data
size for the data link layer. If 32-byte data transmission is selected, only the first 29 bytes

<1>

are used as application

data.

Figure 5

Figure 6 Basic format of data transfer (17-byte data transmission)

<1> The first 30 bytes are used only when the INV_I/O sub-command is used.

Terminator

Master: MP2300 Controller (Example)

MP2300

YASKAWA

TEST

ޓ

ޓ
ޓ

RDY

ALM

TX

RUN

ERR

BAT

MON

CNFG

INT

SUP

STOP

SW1

OFF

ON

BATTERY

CPU I/O

DC24V

DC 0V

M-

I/II

Command data

Station address

Control code

Command code

Data

WDT

Response data

Header of
data link layer

Data link layer data
and application layer

Station address

+00H
+01H

+02H
+03H
+04H

+06H

+11H

+12H

+00H
+01H

+02H
+03H
+04H

+11H

+12H

Control code

Response code

Alarm

Status

Data

EWDT