8 MECHATROLINK-II Commands

YASKAWA ELECTRIC

SIEP C730600 50A YASKAWA AC Drive-Option Card MECHATROLINK-II Technical Manual

25

Table 16 Operation Signals

Use the SEL REF1/2 command to select the contents of REF1 with bits 0 to 3 and to select the contents of REF2 with bits
4 to 7.

Use the SEL MON1/2 command to select the contents of MON1 with bits 0 to 3 and to select the contents of MON2 with
bits 4 to 7.

Table 17

and

Table 18

show the selection ranges for SEL REF1/2 (3/4, 5/6) and SEL MON1/2 (3/4, 5/6).

Table 17 SEL REF1/2 (3/4, 5/6) Selection Range

Bit

<1> Check that the faults has been successfully reset by confirming that the STATUS (RESET) bit has turned OFF.

<2> Errors are not reported while the fault reset signal is ON.

Name

Description

Remarks

0

Forward run

0: Stop
1: Forward run

1

Reverse run

0: Stop
1: Reverse run

2

Multi-function terminal input 3

Terminal S3 input function
0: Terminal S3 function OFF
1: Terminal S3 function ON

H1-03
(Default = 24: External fault (EF3))

3

Multi-function terminal input 4

Terminal S4 input function
0: Terminal S4 function OFF
1: Terminal S4 function ON

H1-04
(Default = 14: Fault reset)

4

Multi-function terminal input 5

Terminal S5 input function
0: Terminal S5 function OFF
1: Terminal S5 function ON

H1-05
(Default = 3: Multi-step speed reference 1)

5

Multi-function terminal input 6

Terminal S6 input function
0: Terminal S6 function OFF
1: Terminal S6 function ON

H1-06
(Default = 4: Multi-step speed reference 2)

6

Multi-function terminal input 7

Terminal S7 input function
0: Terminal S7 function OFF
1: Terminal S7 function ON

H1-07
(Default = 6: Jog command)

7

Multi-function terminal input 8

Terminal S8 input function
0: Terminal S8 function OFF
1: Terminal S8 function ON

H1-08
(Default = 7: External bb command)

8

External fault (EF0)

1: External fault (EF0)

9

Fault reset

<1> <2>

1:

Fault

reset

A to D

Reserved

E

Fault history trace clear

1: Fault history trace clear

F

External BB command

1: External bb command ON

Bit

Item

Remarks

0

Nothing selected

1

Torque Compensation

Unit: 0.1%

2

Analog output terminal 1 output

Enable when H4-01=000

3

Analog output terminal 2 output

Enable when H4-04=000

4

Drive terminal output
Bit0: terminal M1-M2
Bit1: terminal P1-PC
Bit2: terminal P2-PC

terminal M1-M2 (Enable when H2-01=F)
terminal P1-PC (Enable when H2-02=F)
terminal P2-PC (Enable when H2-03=F)

5

PID target

Unit: 0.01%

6

Pulse train output

Unit: 1 Hz

7

V/f gain

8

Reserved

9

Command selection
Bit1: PID target value enable

A to F

Not used.