7 ethercat® option related drive parameters – Yaskawa SI-ES3 for V1000 User Manual

Page 25

Advertising
background image

7 EtherCAT® Option Related Drive Parameters

YASKAWA Europe YEU TOEP C710606 98A - V1000 Option EtherCAT - Installation Manual

EN 25

F6-08

Reset
Communication
Related
Parameters

Determines if communication-related parameters are set back to their
original default values when the drive is initialized.
0: Do not reset F6- and F7- parameters when the drive is
initialized using parameter A1-03.
1: Rest F6- and F7- parameters when the drive is initialized using
parameter A1-03.
Note:

Setting this parameter does not affect communication-

related parameters. Setting this parameter only determines

if communication-related parameters (F6- and F7-

) are also reset when A1-03 is used to initialize the

drive.

0

o1-03

<7>

Digital Operator
Display Selection

Sets the units to display the frequency reference and output frequency.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (enter the number of motor poles to E2-04/E4-04/E5-04)
3: User defined by parameters o1-10 and o1-11

<6>

<1> To start and stop the drive from an EtherCAT

®

master device using serial communications, set b1-02

to 3. To control the frequency reference of the drive via the master device, set b1-01 to 3.

<2> E2-04 is necessary to set up when the Drive Profile DSP402 objects are used.

<3> If set to 3, then the drive will continue to operate when an EF0 fault is detected. Take proper safety

measures, such as installing an emergency stop switch.

<4> This parameter might not appear in certain drives. Furthermore its availability is limited to

depending on the control mode selection. For details refer to the technical manual for the drive the

option card is used with.

<5> If the drive is set to receive the torque reference/limit from the network (F6-06 = 1) make sure the

value is set appropriately by the controller. If no torque reference/limit value is entered the motor

will not produce torque.

<6> The default value depends on the drive used and/or the drive software version. For details refer to

the technical manual for the drive.

<7> Changing o1-03 changes the units for input object 2010 (Hex) (frequency reference), output object

2110 (Hex) (output frequency) and 2200 (Hex) (motor speed). Furthermore o1-03 must be set to 2

and E2-04 must be set to the correct value in order to use the Drive Profile DSP402.

No.

Name

Description

Default

Advertising
This manual is related to the following products: